Make certain that the cable-management
‘
U
’
feature device has the open end pointing upwards when you attach
it to the chassis
Note
Figure 88: Attaching the Cable-Management Brackets to the Cisco ASR 1002 Router
Chassis front rack-mount
bracket
3
Cable-management bracket
top and bottom screw
1
—
—
Cable-management bracket
2
Step 6
Screw the cable-management bracket to each side of the rack-mount brackets already attached to the chassis. Use two
screws for each cable-management bracket. Use the package of four screws.
Step 7
Check that all screws are securely tightened.
Step 8
Go to
Attaching a Chassis Ground Connection, on page 249
the to continue the installation.
Rack-Mounting the Cisco ASR 1002 Router
The Cisco ASR 1002 Router can be installed in an existing rack with equipment or in an empty rack with no
equipment: The chassis can be mounted in either rack types:
•
Two-post rack, either 19 inch or 23 inch. Inner clearance (the width between the inner sides of the two
posts or rails) must be at least 19 inches (48.26 cm). The height of the chassis is 3.47 inches (8.8 cm).
Airflow through the chassis is from front to back.
If you are using a two-post rack secure the rack to the floor surface to prevent tipping and avoid bodily.
Note
Cisco ASR 1000 Series Router Hardware Installation Guide
238
Cisco ASR 1002 Router Overview and Installation
Rack-Mounting the Cisco ASR 1002 Router
Summary of Contents for ASR 1001
Page 2: ... 2013 2017 Cisco Systems Inc All rights reserved ...
Page 20: ...Cisco ASR 1000 Series Router Hardware Installation Guide xx Contents ...
Page 30: ...Cisco ASR 1000 Series Router Hardware Installation Guide xxx Preface Warning Definition ...
Page 32: ...Cisco ASR 1000 Series Router Hardware Installation Guide xxxii Preface Warning Definition ...