Description
Color
LED
LED Label
When the LED is off, it
signals that the
–
48 VDC
output voltage are within
the normal operating
range. Output voltage
between the minimum
and maximum limits will
not create an output fail
alarm, and output
voltages below the
minimum or above the
maximum will create an
Output Fail alarm.
When you turn the power
supply on, the red LED
illuminates for two to
three seconds to test LED
operation before going
off.
Red
Power supply activity
OUTPUT FAIL
AC/DC Power System Output for Cisco ASR 1006
The power supply output tolerance is defined in the following table under all combinations of line variation.
Total system consumption per power supply should not exceed 1200 W.
Table 19: Cisco ASR 1006 Router Power System Output Voltage and Current
+3.3 V
+12 VDC
Output Voltage
3.20 VDC
11.80 VDC
Minimum
3.30 VDC
12.00 VDC
Nominal
3.40 VDC
12.20 VDC
Maximum
Output Current
0.10 A
2.80 A
Minimum
3.125 A
101.7 A
Maximum
Cisco ASR 1000 Series Router Hardware Installation Guide
58
Cisco ASR 1000 Series Routers Component Overview
AC/DC Power System Output for Cisco ASR 1006