If you remove a power supply from a system that has four power supplies that are connected and powered
on, the system can run only for a maximum of five minutes before shutting down. However, because the fans
and power elements are independent within the power supply, the replacement power supply does not have
to be energized within five minutes. The only requirement is that the power supply be installed in the chassis
in order to energize the fans and maintain proper system cooling.
Caution
Step 6
After tightening the receptacle screw for the ground, positive, and negative DC-input leads, use a cable tie to secure the
three leads to the power supply faceplate, as shown in
Figure 142: Cisco ASR 1002-F Router DC Power Supply Terminal
Block Cable Connections, on page 313
. When securing the ground, positive, and negative DC-input leads to the power
supply faceplate, leave a small service loop in the ground lead to ensure that the ground lead is the last lead to disconnect
from the power supply if a great deal of strain is placed on all three leads.
Step 7
Connect the ground, positive, and negative leads to the power source.
Step 8
Turn the branch source breaker on at your site and place the DC Standby switch in the On (|) position.
Step 9
Check that the power supply LEDs light when power is supplied to the router.
What to Do Next
This completes the procedure for connecting a DC power supply in the Cisco ASR 1002-F Router.
Connecting a Terminal to the Cisco Integrated RP Console Port
and Auxiliary Port
Cisco integrated route processor has an asynchronous serial (EIA/TIA-232) RJ-45 console port labeled CON
on its front panel. You can connect this port to most types of video terminals through use of the console cable
kit that is included with your Cisco ASR 1002-F Router. The console cable kit contains:
•
One RJ-45 to RJ-45 crossover cable
•
One RJ-45 to DB-9 (female) adapter
A crossover cable reverses pin connections from one end to the other. In other words, it connects pin 1 (at
one end) to pin 8 (at the other end), pin 2 to pin 7, pin 3 to pin 6, and so on. You can identify a crossover cable
by comparing the two modular ends of the cable. Hold the cable ends in your hand, side-by-side, with the
tabs at the back. Ensure that the wire connected to the outside (left) pin of the left plug (pin 1) is the same
color as the wire connected to the outside (right) pin of the right plug (pin 8).
Use the following procedure to connect a video terminal to the console port on the integrated RP.
Each Cisco ASR 1000 Series route processor must have a console port connection (typically to a terminal
server) if you are running a redundant configuration in the chassis.
Note
Step 1
Connect one end of the RJ-45 cables to the serial console RJ-45 port (CON) on the Cisco integrated RP.
Cisco ASR 1000 Series Router Hardware Installation Guide
314
Cisco ASR 1002-F Router Overview and Installation
Connecting a Terminal to the Cisco Integrated RP Console Port and Auxiliary Port
Summary of Contents for ASR 1001
Page 2: ... 2013 2017 Cisco Systems Inc All rights reserved ...
Page 20: ...Cisco ASR 1000 Series Router Hardware Installation Guide xx Contents ...
Page 30: ...Cisco ASR 1000 Series Router Hardware Installation Guide xxx Preface Warning Definition ...
Page 32: ...Cisco ASR 1000 Series Router Hardware Installation Guide xxxii Preface Warning Definition ...