The following image shows both the AC and DC power supplies for the Cisco ASR 1001 Router.
Figure 214: Cisco ASR 1001 Router AC Power Supply and DC Power Supply
DC power supply positive
(+) connection
5
AC and DC power supply
fasteners
1
DC power supply ground
symbol
6
AC power supply inlet
2
DC power supply
terminal block connection
7
Power supply LED
3
AC and DC power supply
handles
8
DC power supply
negative (-) connection
4
The following table describes the power supply LED. The function of the LED is the same for both the AC
and DC power supplies.
Table 88: Cisco ASR 1001 Router AC and DC Power Supply LED
Description
LED Color and State
Power output is on and within the normal operating
range.
Solid green
Input power that is within the normal operating range
is being supplied, but the Standby switch is in the
Standby position (and not in the On position).
Blinking green, at the rate of one blink per second
A power supply critical event has occurred, and the
power supply has shut down. The critical event can
be temperature, voltage, current, or fan operating
outside the normal operating range.
Solid amber
Cisco ASR 1000 Series Router Hardware Installation Guide
445
Cisco ASR 1001 Router Overview and Installation
Cisco ASR 1001 Router Power Supply Installation
Summary of Contents for ASR 1001
Page 2: ... 2013 2017 Cisco Systems Inc All rights reserved ...
Page 20: ...Cisco ASR 1000 Series Router Hardware Installation Guide xx Contents ...
Page 30: ...Cisco ASR 1000 Series Router Hardware Installation Guide xxx Preface Warning Definition ...
Page 32: ...Cisco ASR 1000 Series Router Hardware Installation Guide xxxii Preface Warning Definition ...