14-105
Cisco ASR 1000 Series Aggregation Services Routers Hardware Installation Guide
OL-13208-11
Chapter 14 Removing and Replacing FRUs from the Cisco ASR 1000 Series Routers
Removing and Replacing the Cisco ASR 1001 Router Power Supplies
Step 5
Ensure that the AC power cords are positioned, as shown in
Figure 14-78
.
Figure 14-78
Correct Position of the Cisco ASR 1001 Router AC Power Supply Cables
Step 6
Plug the AC power supply cables into the AC power source.
Step 7
Turn on the AC breaker.
Step 8
Turn the Standby switch to On (|) on the chassis.
Step 9
The power supply LEDs illuminate green.
This completes the procedure for connecting AC-input power.
Removing AC Power Supply from the Cisco ASR 1001 Router
This section describes how to remove an AC power supply from the Cisco ASR 1001 Router. The Cisco
ASR 1001 Router has two power supply slots, slot 1 next to the Standby switch and power supply slot
zero (PS0) to the left. Follow these steps:
Step 1
On the rear of the router, turn the power switch to the Standby position.
Step 2
Unplug the power cable from the power source.
Step 3
You must remover the top cover from the chassis before you remove any power supply.
1
AC power supply in PS0
3
AC power supply in PS1
2
Position of power supply cable from PS0
—
—
207697
3
2
1