13-2
Cisco ASR 1000 Series Aggregation Services Routers Hardware Installation Guide
OL-13208-11
Chapter 13 Cisco ASR 1000 Series Routers Power Up and Initial Configuration
Verifying Power Supply Operation
•
The console terminal is turned on.
•
You have determined the IP addresses for the Ethernet and serial interfaces.
•
Empty card slots or card bays are filled with card blanks. This ensures proper air flow through the
chassis and electromagnetic compatibility (EMC).
You are now ready to start your router.
Verifying Power Supply Operation
Follow this procedure to verify power supply is operating correctly.
Step 1
Check that the power supply LEDs are:
•
INPUT OK is green
•
FAN OK is green
•
OUTPUT FAILED is not illuminated
Step 2
To ensure that the power supply state is OK, type the
show platform
command. This output sample is
from the Cisco ASR 1013 router. The other Cisco ASR 1000 routers display similar type of output.
The following output displays:
Router#
show platform
Chassis type: ASR1013
Slot Type State Insert time (ago)
--------- ------------------- --------------------- -----------------
0 ASR1000-SIP40 ok 22:56:46
0/0 SPA-5X1GE-V2 ok 22:55:42
0/1 SPA-5X1GE-V2 ok 22:55:36
0/2 SPA-5X1GE-V2 ok 22:55:32
0/3 SPA-5X1GE-V2 ok 22:55:28
1 ASR1000-SIP40 ok 22:56:46
1/0 SPA-5X1GE-V2 ok 22:55:43
1/1 SPA-5X1GE-V2 ok 22:55:40
1/2 SPA-5X1GE-V2 ok 22:55:35
1/3 SPA-5X1GE-V2 ok 22:55:30
2 ASR1000-SIP10 ok 22:56:46
2/0 SPA-5X1GE-V2 ok 22:55:41
2/1 SPA-5X1GE-V2 ok 22:55:33
2/2 SPA-5X1GE-V2 ok 22:55:27
2/3 SPA-5X1GE-V2 ok 22:55:22
3 ASR1000-SIP40 ok 22:56:46
3/0 SPA-3XOC3-ATM-V2 ok 22:55:43
3/1 SPA-4X1FE-TX-V2 ok 22:55:41
3/2 SPA-1XCHSTM1/OC3 ok 22:55:35
3/3 SPA-8XCHT1/E1 ok 22:55:32
4 ASR1000-SIP40 ok 22:56:46
4/0 SPA-1X10GE-L-V2 ok 22:55:43
4/1 SPA-2XCT3/DS0 ok 22:55:41
4/2 SPA-2X1GE-V2 ok 22:55:34
4/3 SPA-1XOC12-POS ok 22:55:32
5 ASR1000-SIP10 ok 22:56:46
5/0 SPA-4XT-SERIAL ok 22:55:39
5/1 SPA-4XOC3-POS ok 22:55:34
5/2 SPA-5X1GE-V2 ok 22:55:26
5/3 SPA-2XT3/E3 ok 22:55:22