Cisco ASR 1000 Series Aggregation Services Routers Hardware Installation Guide
OL-13208-11
Chapter 8 Cisco ASR 1002 Router Overview and Installation
Cisco ASR 1002 Router Power Supplies
This section describes how to connect the –48 VDC power supply in the Cisco ASR 1002 Router.
Note
The color coding of the –48 VDC input power supply leads depends on the color coding of the –48 VDC
power source at your site. Typically, green or green/yellow is used for ground. Make certain the lead
color coding you choose for the –48 VDC input power supply matches lead color coding used at the –48
VDC power source.
Warning
When you install the unit, the ground connection must always be made first and disconnected last.
Statement 1046
Step 1
At the rear of the router, check that the power supply Standby switch is in the Standby (see
Figure 8-27
)
position.
Figure 8-27
Cisco ASR 1002 Router –48 VDC Power Supply Terminal Block Cable Connections
OUTPUT
FAIL
Power supply activity
Red
When the LED is off, it signals that the –48 VDC output voltage are
within the normal operating range. Output voltage between the
minimum and maximum limits will not create an output fail alarm,
and output voltages below the minimum or above the maximum will
create an Output Fail alarm.
Led illuminates red to indicate that the –48 VDC output is out of the
specified range.
When you turn the power supply on, the red LED illuminates for two
to three seconds to test LED operation before going off.
Table 8-10
Cisco ASR 1002 Router –48 VDC Power Supply LEDs
LED Label
LED
Color
Description
1
Ground lead with service loop and tie-wrap
3
Negative lead
2
Positive lead
4
–48 VDC power supply Standby switch
OUTPUT INP
UT
FAIL
OK
OK
FAN
-48V/-60V 16
A
This unit might h
ave more than
one power supp
ly connection.
All connections m
ust be removed
to de-energize the unit.
3
1
2
280290
4