14-103
Cisco ASR 1000 Series Aggregation Services Routers Hardware Installation Guide
OL-13208-11
Chapter 14 Removing and Replacing FRUs from the Cisco ASR 1000 Series Routers
Removing and Replacing the Cisco ASR 1001 Router Power Supplies
Installing the AC Power Supply into Cisco ASR 1001 Router
The Cisco ASR 1001 Router has two AC power supplies at the rear of the chassis. The input receptacle
is an IEC60320 C14 type of filtered AC Inlet. The current rating on the connector is 10 A.
Figure 14-76
shows the ASR 1001 Router AC power supply.
Figure 14-76
Cisco ASR 1001 Router AC Power Supply
To connect an AC-input power supply to the Cisco ASR 1001 Router, follow these steps:
Step 1
There are two power supplies installed. At the rear of the chassis, check whether the power switch on
the chassis is in the Standby position.
Warning
Do not install the Cisco ASR 1001 Router power supplies without the top cover on the Cisco ASR 1001
chassis.
207700
0