8-41
Cisco ASR 1000 Series Aggregation Services Routers Hardware Installation Guide
OL-13208-11
Chapter 8 Cisco ASR 1002 Router Overview and Installation
Cisco ASR 1002 Router Power Supplies
Step 4
Using a 3.5mm screwdriver, insert the screwdriver at an angle to release the spring while you install the
stripped lead wire as shown in
Figure 8-30
.
Figure 8-30
Inserting a Screwdriver Into the +24 VDC Power Supply Terminal Block
Step 5
Carefully push the screwdriver at an angle forward until you relieve the spring contact.
Step 6
With the screwdriver still inserted, gently push the lead wire (ground lead first) in until the copper wire,
as shown in
Figure 8-31
, is no longer visible (see
Figure 8-32
).
Caution
Check that there is no copper portion of the lead wire exposed. You only want the wire insulation visible.
Caution
Do not install wire into the terminal block that has not had its insulation removed.
Figure 8-31
Cisco ASR 1002 24 VDC Power Supply Lead Wire Inserted into Terminal Block
253166
OUTPUT
INPUT
FAIL
OK
OK
FAN
This unit might ha
ve more than
one po
wer supply connection.
All connections m
ust be remo
ved
to de-energiz
e the unit.
+27V DC INPUT
+27V 32A
1
Lead wire insulation
2
Copper wire
253167
OUTPUT
INPUT
FAIL
OK
OK
FAN
This unit might ha
ve more than
one po
wer supply connection.
All connections m
ust be remo
ved
to de-energiz
e the unit.
+27V DC INPUT
+27V 32A
1
2