11-8
Cisco ASR 1000 Series Aggregation Services Routers Hardware Installation Guide
OL-13208-11
Chapter 11 Cisco ASR 1013 Router Overview and Installation
Installation Methods
Cisco ASR 1013 Router Slot Numbering
The Cisco ASR 1013 chassis has two Cisco ASR100-RP2 (R0, R1) slots, two embedded services
processor slots (F0, F1) and six dedicated Cisco ASR1000-SIP slots (from bottom of chassis up, 0, 1, 2,
3, 4, 5 respectively).
The Cisco ASR 1013 Router is designed with each slot numbered as shown in
Figure 11-2
.
Note
Cisco ASR 1013 slots are keyed using rotated guide pins for the plug-in card to be fully inserted in slots
where they are intended to operate. This keyed feature prevents cards from being inserted into the wrong
slots.
The Cisco ASR 1013 Router contains three SPA Interface Processor (SIPs) slots and supports four
subslots for the installation of SPAs.
Figure 11-3
shows the Cisco ASR 1013 Router SPA subslot
location.
Figure 11-3
Cisco ASR 1013 Router—ASR1000-SIP Subslots
Installation Methods
One set of forward rack-mount brackets come pre-installed on the Cisco ASR 1013 Router as shown in
Figure 11-2
, callout number 2. The accessory kit contains the rear rack-mount brackets as shown in
Figure 11-2
, callout number 4, which are optional and another set of forward rack-mount brackets.
You can mount the chassis in a19-inch wide (standard), 4-post equipment rack or two-post, using the
rack-mount brackets in the accessory kit. The Cisco ASR 1013 Router supports 6 SIPs and provides
superslots (more height and power) for the Cisco ASR1000-RP2s and Cisco ASR1000-ESP cards.
Note
The Cisco ASR 1013 Router usually ships fully loaded. However, you can remove components from the
chassis to make the chassis lighter for your rack installation.
General Rack Installation Guidelines
When planning your rack installation, consider the following guidelines:
•
The Cisco ASR 1013 Router overall height is 22.75 inches (57.8 cm). You can install three Cisco
ASR 1013 routers in a 42RU equipment rack; but must allow at least one to two inches (2.54 cm to
5.08 cm) of vertical clearance between the router and any equipment above or below it. Measure the
proposed rack location before mounting the chassis in the rack.
S
PA 0
S
PA 1
S
PA 2
S
PA 3
Front of
S
IP, horizontal chassis slots
23150