14-58
Cisco ASR 1000 Series Aggregation Services Routers Hardware Installation Guide
OL-13208-11
Chapter 14 Removing and Replacing FRUs from the Cisco ASR 1000 Series Routers
Removing and Replacing the Cisco ASR 1006 Router Power Supplies
Figure 14-39
shows the ASR1013/06-PWR-AC power supply of the Cisco ASR 1006 Router.
Figure 14-39
Cisco ASR 1006 Router AC Power Supply (ASR1013/06-PWR-AC)
Step 1
Insert an AC power supply in power supply slot 0 or power supply slot 1 until it is fully seated.
Step 2
Tighten the captive screws.
Step 3
Insert the AC power cable.
Step 4
Plug the power supply cable into the power source.
Step 5
Turn the power supply Standby switch to the On (|) position.
This completes the procedure for installing the AC power supply in the Cisco ASR 1006 Router.
Removing and Replacing a DC Power Supply in Cisco ASR 1006 Router
This section provides information about removing and installing a DC power supply in the Cisco
ASR 1006 Router.
Warning
When you install the unit, the ground connection must always be made first and disconnected last.
Statement 1046
1
AC power supply fan
6
AC power inlet
2
DB-25 alarm connector
7
AC power supply Standby switch
3
Tie-wrap tab
8
Protective shielding on both sides of the Standby
switch
4
AC power supply captive screw
9
AC power supply LEDs
5
AC power supply handle
—
—
253916
OUTPUT INPUT
INPUT
FAIL
OK
OK
ALARM
S
60V
1A MAX
100-240V~ 16-7A
50-60HZ
This unit might have more than
one power supply connection.
All connections must be removed
to de-energize the unit.
2
1
3
4
5
6
7
9
8