Chapter 8 Cisco ASR 1002 Router Overview and Installation
Cisco ASR 1002 Router Power Supplies
Figure 8-34
shows all the lead wires installed.
Figure 8-34
Cisco +24 VDC Power Supply Terminal Block With Lead Wires Installed
Note
Make sure the stripped end of each lead wire is twisted tightly together. This makes insertion
easier. Then make certain the entire lead wire is inserted all the way into its receptacle. If any
exposed wire at the stripped end of a lead is visible after inserting the lead into its receptacle,
remove the lead from the receptacle, use the wire stripper to cut the stripped end of the lead, and
then reinsert.
Caution
When securing the ground, positive, and ne24 VDC-input leads to the power supply faceplate,
leave extra service loop in the ground (GND) lead to ensure that the ground lead is the last lead wire to
disconnect from the power supply if a great deal of strain is placed on all three leads.
1
Positive lead wire
3
Ground lead wire
2
Negative lead wire
—
—