Cisco ASR 1000 Series Aggregation Services Routers Hardware Installation Guide
OL-13208-11
Chapter 1 Cisco ASR 1000 Series Routers Hardware Overview
Functional Overview
Queued messages:
%ENVM-1-SHUTDOWN: Environmental Monitor initiated shutdown
Reporting Functions
The chassis manager on the forwarding engine control processor manages the local resources of the
forwarding processor. It manages the ESI (Enhanced Serdes Interconnect) which are the datapath links
on the midplane connecting the Cisco ASR 1000 Series RP1s, SIPs, and standby ESP modules to the
active Cisco ASR 1000 Series Embedded Services Processor. It communicates with the chassis manager
on the Cisco ASR 1000 Series Route Processor 1 to report the status and health, including detected
hardware failures, ESI status, software process status, and the state of thermal sensors.
The Cisco ASR 1000 Series Routers display warning messages on the console if the chassis
interface-monitored parameters exceed a threshold. You can also retrieve and display environmental
status reports with the following commands:
•
show environment all
•
show
version
•
show inventory
•
show platform
•
show platform software status control-processor
•
show diag
Parameters are measured and reporting functions are updated every 60 seconds. A brief description of
each of these commands follows.
Note
The example outputs displayed in this section are from the Cisco ASR 1004 Router. Similar output is
displayed for all Cisco ASR 1000 Series Routers.
Example 1-1
show environment all Command
Router#
show environment all
Sensor List: Environmental Monitoring
Sensor Location State Reading
V1: VMA F0 Normal 1791 mV
V1: VMB F0 Normal 1196 mV
V1: VMC F0 Normal 1191 mV
V1: VMD F0 Normal 1093 mV
V1: VME F0 Normal 996 mV
V1: 12v F0 Normal 11894 mV
V1: VDD F0 Normal 3261 mV
V1: GP1 F0 Normal 900 mV
V2: VMA F0 Normal 3286 mV
V2: VMB F0 Normal 2495 mV
V2: VMC F0 10% high 1796 mV
V2: VMD F0 Normal 1093 mV
V2: VME F0 Normal 996 mV
V2: VMF F0 Normal 996 mV
V2: 12v F0 Normal 11850 mV
V2: VDD F0 Normal 3261 mV
V2: GP1 F0 10% high 898 mV
Temp: Inlet F0 Normal 29 Celsius
Temp: Asic1 F0 Normal 47 Celsius