7
7
7-40
7-40
Installation > Adjustment > Side Registration/Skew Adjustment > Skew Adjustment
Installation > Adjustment > Side Registration/Skew Adjustment > Skew Adjustment
■
Side Rregistration Adjustment
1) Execute shutdown sequence, and then turn OFF the power of the host machine and
Finisher.
2) Separate the Finisher from the upstream equipment.
• Disconnect the power plug from the outlet.
• Disconnect the power cable of the finisher.
• Disconnect the ARCNET cable.
• Remove the shunt cable.
• Remove the Latch Receivers (Front and Rear)
3) Loosen the 2 screws on the Positioning Plate at the right side.
4) If the value obtained at "Checking Adjustment Value" is "+ (positive)", move it in [A]
direction and tighten the 2 screws.
If the value obtained at "Checking Adjustment Value" is "- (negative)", move it in [B]
direction and tighten the 2 screws.
[B]
[A]
Screw
F-7-113
■
Skew Adjustment
CAUTION:
If the skew adjustment value is within the range, start from step 8).
1) Remove the 3 Knobs.
• 3 Claws
Knob
Claw
CAUTION:
When the One-way Clutch inside the knob is removed, be sure to install it in the
direction where the arrow marking of the One-way Clutch is visible.
F-7-115
F-7-114
Summary of Contents for Finisher-AK1
Page 8: ... Notes Before Servicing Points to Note at Cleaning Safety Precautions ...
Page 10: ...1 1 Product Outline Product Outline Product Specifications Names of Parts ...
Page 55: ...3 3 Periodic Servicing Periodic Servicing User Maintenance Maintenance and Inspection ...
Page 309: ...6 6 Troubleshooting Troubleshooting Upgrading ...
Page 361: ... Service Tools Solvents and Oils List of Signals General Circuit Diagram Appendix ...