5
5
5-60
5-60
Adjustment > Adjustment at Time of Parts Replacement > Adjustment in the Case of Canceling Limit for Tray Stack > Procedure
Adjustment > Adjustment at Time of Parts Replacement > Adjustment in the Case of Canceling Limit for Tray Stack > Procedure
Adjustment in the Case of Canceling Limit for Tray
Stack
Execute this adjustment in the case of canceling the limit for tray stacking of coated paper or
extra-length paper or replacing the finisher controller PCB.
[A]
[B]
[A] Normal stacking
[B] Stacking while stacking limit is cancelled
NOTE:
This adjustment is for the lower tray only. Thus, cancellation of the stacking limit for the
upper tray is not available.
Following table shows stacking capacity for the lower tray while the stacking limit is
cancelled.
Paper type
At normal operation
When stacking limit is
canceled
Plain paper
Half
Less than 64
gsm
1,000 sheets
Up to 147 mm in height
80 gsm or less
4,000 sheets
Up to 490 mm in height
Over 80 gsm
3,000 sheets
Up to 147 mm in height
Stitching
200 sets or 3,000 sheets
200 sets
Extra-large
Up to 147 mm in height
Up to 216 mm in height
Coated
paper
Half
80 gsm or less
4,000 sheets
Up to 490 mm in height
Over 80 gsm
3,000 sheets
Up to 490 mm in height
Stitching
200 sets or 3,000 sheets
200 sets
Extra-large
Up to 147 mm in height
Up to 216 mm in height
F-5-141
T-5-7
■
Preparations
1) Turn ON the power of the finisher.
2) Turn ON the power of the host machine to be on to be on standby.
3) Open the front cover and put the door switch tool into the door switch.
4) Remove the switch cover.
NOTE:
Refer to "Preparations 5-6" for details of step 1) to 4).
■
Procedure
1) Set DIP SW382 [1] on the switch PCB as shown in the figure below.
SW382
SW381
SW383
(-)
(+)
ENTER
SW384 SW385
DSP381
[1]
F-5-142
Summary of Contents for Finisher-AK1
Page 8: ... Notes Before Servicing Points to Note at Cleaning Safety Precautions ...
Page 10: ...1 1 Product Outline Product Outline Product Specifications Names of Parts ...
Page 55: ...3 3 Periodic Servicing Periodic Servicing User Maintenance Maintenance and Inspection ...
Page 309: ...6 6 Troubleshooting Troubleshooting Upgrading ...
Page 361: ... Service Tools Solvents and Oils List of Signals General Circuit Diagram Appendix ...