Parts Replacing and Cleaning > Feed Assembly > Removing the Side Registration Sensor PCB > Procedure
Parts Replacing and Cleaning > Feed Assembly > Removing the Side Registration Sensor PCB > Procedure
Removing the Side Registration Sensor PCB
■
Preparation
1) Open the Front Cover.
2) Separate the finisher from the host machine.(Refer to page 4-18)
3) Remove the Rear Upper Cover (Right).(Refer to page 4-21)
4) Remove the Rear Upper Cover (Left).(Refer to page 4-21)
5) Remove the Rear Cover.(Refer to page 4-20)
6) Remove the Inner Cover (Upper) (when the Puncher Unit is installed).(Refer to page 4-22)
7) Remove the Puncher Unit (when the Puncher Unit is installed).(Refer to page 4-46)
8) Remove the Side Registration Sensor Unit.(Refer to page 4-47)
■
Procedure
1) Place the Side Registration Sensor Unit in the direction as shown in the figure below.
2) Remove the 2 plates [1].
• 4 Screws [2]
[1]
[2]
[2]
F-4-99
3) Remove the Shift Shaft [1].
• 1 Screw [2]
4) Remove the screw [4] from the Shift Shaft [3].
[3]
[2]
[4]
[1]
5) Move the Guide Cover [1].
• 2 Screws [2]
6) Remove the Shift Shaft [3] from the Shaft Support [4].
[2]
[2]
[3]
[4]
[1]
x2
F-4-100
F-4-101
Summary of Contents for Finisher-AK1
Page 8: ... Notes Before Servicing Points to Note at Cleaning Safety Precautions ...
Page 10: ...1 1 Product Outline Product Outline Product Specifications Names of Parts ...
Page 55: ...3 3 Periodic Servicing Periodic Servicing User Maintenance Maintenance and Inspection ...
Page 309: ...6 6 Troubleshooting Troubleshooting Upgrading ...
Page 361: ... Service Tools Solvents and Oils List of Signals General Circuit Diagram Appendix ...