Parts Replacing and Cleaning > Intermediate Process Tray Assembly > Removing the Process Tray Plate Unit > Procedure
Parts Replacing and Cleaning > Intermediate Process Tray Assembly > Removing the Process Tray Plate Unit > Procedure
Removing the Stack Delivery Motor
■
Preparation
1) Remove the Stack Wall (Lower).(Refer to page 4-29)
2) Remove the Stack Wall (Upper).(Refer to page 4-27)
3) Remove the Neat Stack Unit (Lower).(Refer to page 4-59)
4) Remove the Process Tray Unit.(Refer to page 4-62)
■
Procedure
1) Loosen the screw [1] to remove the Stack Delivery Motor [2].
• 1 Connector [3]
• 2 Screws [4]
• 1 Belt [5]
[3]
[2]
[1]
[5]
[4]
[4]
x2
F-4-171
Removing the Process Tray Plate Unit
■
Preparation
1) Remove the Stack Wall (Lower).(Refer to page 4-29)
2) Remove the Stack Wall (Upper).(Refer to page 4-27)
3) Remove the Neat Stack Unit (Lower).(Refer to page 4-59)
4) Remove the Process Tray Unit.(Refer to page 4-62)
■
Procedure
1) Free the harness from the 3 Wire Saddles [1], and disconnect the connector [3].
[1]
[2]
[3]
[1]
x3
F-4-172