7
7
7-19
7-19
Installation > Installation Procedure > Connecting with the Paper Folding Unit
Installation > Installation Procedure > Connecting with the Paper Folding Unit
4) Lift the Latch Plate (Front) up and lock it on the cover, and connect the Finisher and the
Paper Folding Unit by fitting the Positioning Pin of the Paper Folding Unit into the hole on
the Positioning Plate of the Finisher.
< Front side >
Latch Plate (Front)
< Rear side >
Hole
Positioning Pin
F-7-49
F-7-50
CAUTION:
When connecting the inner side, take caution not to get the cable pinched.
F-7-51
5) Lower the Latch Plate (Front) and fix it.
• 1 Screw (Use the Screw removed in the step 7) of "Before Installing the Finisher")
Screw
Latch Plate (Front)
6) Close the Finisher Front Cover.
F-7-52