7
7
7-39
7-39
Installation > Adjustment > Side Registration/Skew Adjustment > Checking Adjustment Value
Installation > Adjustment > Side Registration/Skew Adjustment > Checking Adjustment Value
3) Remove the Switch Cover of the Inner Cover (Lower).
• 1 Screw
●
Procedure
1) Be sure to write down the setting of DIP switch SW382 on the Switch PCB.
2) Set DIP switch SW382 on the Switch PCB as shown in the figure (1, 4, 6, 8: ON), and
press ENTER button (SW385), resulting in "0" blinks on the LED (DSP381).
SW382
SW381
SW383
(-)
(+)
ENTER
SW384 SW385
DSP381
F-7-110
F-7-111
3) Place a sheet of A4 or LTR paper and set in ADF or the copyboard mode, and set "3" for
copy count to execute printing.
4) The LED (DSP381) displays the adjustment value for side registration/skew.
Check each value. The display shows values in the order of "A" > "side registration
adjustment value" > "B" > "skew adjustment value".
• Side registration adjustment range (estimated value) : -3 to +3 mm (1 scale is equivalent to
1mm)
• Skew adjustment range (estimated value) : -2 to +2 mm (1 scale is equivalent to 1mm)
SW382
SW381
SW383
(-)
(+)
ENTER
SW384 SW385
DSP381
5) Press ENTER button (SW385) to complete the adjustment mode.
If the adjustment value (estimated value) is within the range, put the DIP switch setting
back and install the removed covers/parts.
If the adjustment value (estimated value) is out of the range, execute "Side registration
adjustment" or "Skew adjustment".
F-7-112
Summary of Contents for Finisher-AK1
Page 8: ... Notes Before Servicing Points to Note at Cleaning Safety Precautions ...
Page 10: ...1 1 Product Outline Product Outline Product Specifications Names of Parts ...
Page 55: ...3 3 Periodic Servicing Periodic Servicing User Maintenance Maintenance and Inspection ...
Page 309: ...6 6 Troubleshooting Troubleshooting Upgrading ...
Page 361: ... Service Tools Solvents and Oils List of Signals General Circuit Diagram Appendix ...