Adjustment > Auxiliary Adjustment > Adjusting Staple Position (2-stapling positions) > Procedure
Adjustment > Auxiliary Adjustment > Adjusting Staple Position (2-stapling positions) > Procedure
3) Pressing switch SW383 [1] or SW384 [2] determines adjustment level.
By pressing SW383 once, the LED [3] indicates "-1" and the 2 stapling positions shift to the
upper side. In the same way, by pressing SW384 once, the LED [3] indicates "+1" and the
2 stapling positions shift to the lower side.
• Adjustment range: +20 to -20 (shifting amount per unit: 0.5mm)
SW382
SW381
SW383
(-)
(+)
ENTER
SW384 SW385
DSP381
[1]
[2]
[3]
4) Press switch SW385 [1] to move the stapler to the 2-stapling position.
SW382
SW381
SW383
(-)
(+)
ENTER
SW384 SW385
DSP381
[1]
F-5-178
F-5-179
5) Place A4 paper [1] on the intermediate process tray (Be sure to push in the paper to the
rear side of the process tray).
[1]
6) Check that the stapling position is within the specified range [1] (81.7 +/- 4mm for
A-configuration, 72.7 +/- 4mm for L-configuration). If the stapling position is out of the
specification, go through the procedure again from step 2).
[1]
7) Once the adjustment is complete, press SW385 to complete the adjustment mode.
CAUTION:
If the LED indicates anything other than "0" meaning the adjustment failure, execute the
adjustment again.
F-5-180
F-5-181
Summary of Contents for Finisher-AK1
Page 8: ... Notes Before Servicing Points to Note at Cleaning Safety Precautions ...
Page 10: ...1 1 Product Outline Product Outline Product Specifications Names of Parts ...
Page 55: ...3 3 Periodic Servicing Periodic Servicing User Maintenance Maintenance and Inspection ...
Page 309: ...6 6 Troubleshooting Troubleshooting Upgrading ...
Page 361: ... Service Tools Solvents and Oils List of Signals General Circuit Diagram Appendix ...