Installing connectorized antennas
Chapter 5: Installation
5-10
phn-2510_002v000 (Mar 2012)
5
When dressing the antenna cables, form drip loops near the lower ends. These
ensure that water is not constantly channeled towards the connectors.
6
If the ODU is mounted outdoors, weatherproof the N type connectors fitted to the
ODU by following the procedure
Weatherproofing an N type connector
on page
5-
11
. Weatherproof the antenna joints in the same way (unless the antenna
manufacturer specifies a different method).
7
Ground the antenna cables to the supporting structure at the correct points. They
should be grounded within 0.3 meters (1 foot) of the ODU and antennas using the
cable grounding kit (part number 01010419001):
A mast or tower may require additional grounding points, as specified in
Protection requirements for a mast or tower installation