Grounding and lightning protection
Chapter 2: Planning considerations
2-18
phn-2510_002v000 (Mar 2012)
Figure 13
Grounding cable minimum bend radius and angle
Radius not less
than 203 mm (8 in)
Angle not less
than 90°
ODU requirements
The following ODU protection requirements must be implemented:
x
The ODU must be grounded to the supporting structure.
Protection requirements for a mast or tower installation
If the ODU is to be mounted on a metal tower or mast, then in addition to the general
protection requirements (above), the following requirements must be observed:
x
The equipment must be lower than the top of the tower or its lightning air terminal.
x
The metal tower or mast must be correctly grounded.
x
A grounding kit must
be installed at the first point of contact between the drop cable
and the tower, near the top.
x
A grounding kit must be installed at the bottom of the tower, near the vertical to
horizontal transition point. This grounding kit must
be bonded to the tower or tower
ground bus bar (TGB), if installed.
x
If the tower is greater than 61 m (200 ft
)
in height, an additional grounding kit must be
installed at the tower midpoint. Additional ground kits must be installed as necessary
to reduce the distance between ground kits to 61 m (200 ft) or less.
x
In high lightning prone geographical areas, additional ground kits should be installed
at spacing between 15 to 22 m (50 to 75 ft
)
. This is especially important on towers
taller than 45 m (150 ft).
A schematic example of a mast or tower installation is shown in
Figure 14
.
Summary of Contents for PTP 250
Page 1: ...Cambium PTP 250 User Guide System Release 250 02 01 ...
Page 8: ...Safety and regulatory information VI phn 2510_002v000 Mar 2012 ...
Page 20: ...List of Tables xii phn 2510_002v000 Mar 2012 ...
Page 58: ...System management Chapter 1 Product description 1 30 phn 2510_002v000 Mar 2012 ...
Page 104: ...Limit of liability Chapter 3 Legal information 3 12 phn 2510_002v000 Mar 2012 ...
Page 122: ...Notifications Chapter 4 Reference information 4 18 phn 2510_002v000 Mar 2012 ...
Page 152: ...Installing the PoE power supply Chapter 5 Installation 5 30 phn 2510_002v000 Mar 2012 ...