Managing link status and alerts
Chapter 7: Operation
7-14
phn-2510_002v000 (Mar 2012)
Table 44
Wireless Link Status attribute values
Value
Meaning
Up
The wireless link is up and running.
Registering
The wireless link is up, but not yet running (still handshaking,
setting security and so on).
Acquiring
The Master unit is waiting for a slave. Only displayed at a Master
unit.
Searching
At a Master unit: searching for a quality channel.
At a Slave unit: searching for a Master.
Radar CAC
Radar Channel Availability Check (CAC) in progress.
Initializing
The unit is starting up or resetting (for example, for a
configuration change or because radar has been detected).
No Channels
Radar CAC has determined that there are no useable channels.
Managing email alerts
The management agent can be configured to generate alerts by electronic mail when
certain events occur. The email message configuration procedure is described in
Step 3:
SNMP/SMTP configuration
on page
6-16
. The alerts are defined in
Table 45
.
Table 45
Email alerts
Alert
Meaning
Cold Start
The unit has rebooted.
Link Down
The link is down.
Link Up
The link is up.
Summary of Contents for PTP 250
Page 1: ...Cambium PTP 250 User Guide System Release 250 02 01 ...
Page 8: ...Safety and regulatory information VI phn 2510_002v000 Mar 2012 ...
Page 20: ...List of Tables xii phn 2510_002v000 Mar 2012 ...
Page 58: ...System management Chapter 1 Product description 1 30 phn 2510_002v000 Mar 2012 ...
Page 104: ...Limit of liability Chapter 3 Legal information 3 12 phn 2510_002v000 Mar 2012 ...
Page 122: ...Notifications Chapter 4 Reference information 4 18 phn 2510_002v000 Mar 2012 ...
Page 152: ...Installing the PoE power supply Chapter 5 Installation 5 30 phn 2510_002v000 Mar 2012 ...