Site planning
Chapter 2: Planning considerations
2-6
phn-2510_002v000 (Mar 2012)
Site planning
This section describes factors to be taken into account when choosing sites for the ODU
and PoE power supply.
ODU site selection
When selecting a site for the ODU, consider the following factors:
x
Height and location to ensure that people are kept away from the antenna; see
Calculated distances and power compliance margins
on page
4-10
.
x
Height and location to achieve the best radio path.
x
Ability to meet the requirements specified in
Grounding and lightning protection
on
page
2-15
.
x
Aesthetics and planning permission issues.
x
Cable lengths; see
Maximum cable lengths
on page
2-7
.
x
The effect of strong winds on the installation; see
Wind loading
on page
2-7
.
Power supply selection
Select a suitable power supply unit for the PTP 250. The only supported units are the PoE
power supply (included in PTP 250 kits) or the PTP 300/500/600 Series PIDU. The PoE
power supply is suitable for the majority of installations, but the PIDU is required in the
following situations:
x
When a -48 V DC power supply is required, either as the primary supply or as a backup
to the AC mains.
x
When an extended operating temperature range is required for the mains powering
system, for example when the indoor equipment is in a building without temperature
control or air conditioning.
For PIDU ordering information, see
Alternative and additional components
on page
2-34
.
The power supply unit must be installed in an indoor location with no possibility of
condensation, with an ambient temperature within the specified operating range of the
product; see
Power supply unit specifications
on page
4-3
.
Summary of Contents for PTP 250
Page 1: ...Cambium PTP 250 User Guide System Release 250 02 01 ...
Page 8: ...Safety and regulatory information VI phn 2510_002v000 Mar 2012 ...
Page 20: ...List of Tables xii phn 2510_002v000 Mar 2012 ...
Page 58: ...System management Chapter 1 Product description 1 30 phn 2510_002v000 Mar 2012 ...
Page 104: ...Limit of liability Chapter 3 Legal information 3 12 phn 2510_002v000 Mar 2012 ...
Page 122: ...Notifications Chapter 4 Reference information 4 18 phn 2510_002v000 Mar 2012 ...
Page 152: ...Installing the PoE power supply Chapter 5 Installation 5 30 phn 2510_002v000 Mar 2012 ...