Installing the ODU
Chapter 5: Installation
5-6
phn-2510_002v000 (Mar 2012)
Mounting the ODU
To mount the ODU, proceed as follows:
1
Attach the ODU bracket strap to the pole using M8 x 40 mm or M8 x 70 mm bolts,
M8 flat washers and M8 coil washers.
Tighten to ensure the assembly grips, but can be adjusted on the pole.
2
Use the integral safety loop (
Figure 22
) to hoist the ODU up to the bracket,
observing the precautions described in
Checks and safety precautions
on page
5-4
.
3
When the ODU is in position, use the safety loop as a fixing point to secure a
permanent safety lanyard from the supporting structure to the ODU, as a
precaution against mounting failure.
4
Offer the ODU (with pre-fitted mounting bracket) to the bracket strap and affix
using the captive M8 bolt. Tighten to ensure the assembly grips, but can be
adjusted on the pole.
5
Adjust the elevation and azimuth of the unit to achieve an approximate visual
alignment (does not apply to connectorized ODUs). Tighten both bolts to the
required torque settings of 14 Nm (11 lb ft).
Do not over-tighten the bolts, as this may lead to failure of the assembly.
Summary of Contents for PTP 250
Page 1: ...Cambium PTP 250 User Guide System Release 250 02 01 ...
Page 8: ...Safety and regulatory information VI phn 2510_002v000 Mar 2012 ...
Page 20: ...List of Tables xii phn 2510_002v000 Mar 2012 ...
Page 58: ...System management Chapter 1 Product description 1 30 phn 2510_002v000 Mar 2012 ...
Page 104: ...Limit of liability Chapter 3 Legal information 3 12 phn 2510_002v000 Mar 2012 ...
Page 122: ...Notifications Chapter 4 Reference information 4 18 phn 2510_002v000 Mar 2012 ...
Page 152: ...Installing the PoE power supply Chapter 5 Installation 5 30 phn 2510_002v000 Mar 2012 ...