Compliance with safety standards
Chapter 4: Reference information
4-10
phn-2510_002v000 (Mar 2012)
Calculation of power density
The following calculation is based on the ANSI IEEE C95.1-1991 method, as that provides
a worst case analysis. Details of the assessment to EN50383:2002 can be provided, if
required.
Peak power density in the far field of a radio frequency point source is calculated as
follows:
Where:
Is:
S
power density in W/m
2
P
maximum average transmit power
capability of the radio, in W
G
total Tx gain as a factor, converted
from dB
d
distance from point source, in m.
Rearranging terms to solve for distance yields:
Calculated distances and power compliance margins
Table 30
shows calculated minimum separation distances, recommended distances and
resulting margins for each frequency band and antenna combination. These are
conservative distances that include compliance margins. At these and greater separation
distances, the power density from the RF field is below generally accepted limits for the
general population.
Explanation of terms used in
Table 30
:
Tx burst – maximum average transmit power in burst (Watt)
P – maximum average transmit power capability of the radio (Watt)
G – total transmit gain as a factor, converted from dB
S – power density (W/m
2
)
d – minimum distance from point source (meters)
R – recommended distances (meters)
2
4
.
d
G
P
S
S
S
G
P
d
.
4
.
S
Summary of Contents for PTP 250
Page 1: ...Cambium PTP 250 User Guide System Release 250 02 01 ...
Page 8: ...Safety and regulatory information VI phn 2510_002v000 Mar 2012 ...
Page 20: ...List of Tables xii phn 2510_002v000 Mar 2012 ...
Page 58: ...System management Chapter 1 Product description 1 30 phn 2510_002v000 Mar 2012 ...
Page 104: ...Limit of liability Chapter 3 Legal information 3 12 phn 2510_002v000 Mar 2012 ...
Page 122: ...Notifications Chapter 4 Reference information 4 18 phn 2510_002v000 Mar 2012 ...
Page 152: ...Installing the PoE power supply Chapter 5 Installation 5 30 phn 2510_002v000 Mar 2012 ...