PTP 250 User Guide
Installing the drop cable and LPU
phn-2510_002v000 (Mar 2012)
5-19
Connecting an RJ45 and gland to a unit
Perform this task to connect the drop cable to an ODU or LPU. This procedure contains
illustrations of an ODU, but it applies in principle to both the ODU and the LPU.
To connect the drop cable with a gland to a unit (LPU or ODU), proceed as follows:
1
Insert the RJ45 plug into the socket in the unit, making sure that the locking tab
snaps home.
2
Support the drop cable and gently hand screw the gland body into the unit until
the O ring seal is flush to the unit body.
Do not fit the back shell prior to securing the gland body.
3
Once the gland is fully hand screwed into the unit, tighten it with a spanner to
torque 10 Nm (7.4 ftlbs).