No device (ODU) detected
LED state:
PoE type 9001GR: PORT is on yellow (steady).
PoE type PD7001: AC is on green (steady) and PORT is off.
Meaning
: The PoE power supply is receiving power from an AC outlet, but no device
(ODU) is detected at the DATA & POWER OUT port.
Action
: Test the network and ODU connections:
x
Remove the network cable from the DATA IN port. Examine it for signs of damage.
Replace it if it is supect.
x
Remove the ODU cable from the DATA & POWER OUT port. Examine it for signs of
damage. Check that the ODU cable resistances are correct, as specified in
Testing
resistance in the ODU cable
on page
8-8
. Replace it if it is suspect.
Device (ODU) detected
LED state:
PoE type 9001GR: PORT is on green (steady).
PoE type PD7001: AC and PORT are on green (steady).
Meaning
: A device (ODU) is detected at the DATA & POWER OUT port.
Action
: If, in spite of this, a fault is suspected in the link end hardware, check for the error
condition described in the following note:
If the ODU is disconnected from the LPU but the LPU remains connected to the PoE, the
Port LED may remain in the green (steady) state. The Port LED will only return to yellow
if the LPU is disconnected.
If this error is not found, follow the Ethernet packet test flowchart (
Figure 57
) and
procedures below.
Summary of Contents for PTP 250
Page 1: ...Cambium PTP 250 User Guide System Release 250 02 01 ...
Page 8: ...Safety and regulatory information VI phn 2510_002v000 Mar 2012 ...
Page 20: ...List of Tables xii phn 2510_002v000 Mar 2012 ...
Page 58: ...System management Chapter 1 Product description 1 30 phn 2510_002v000 Mar 2012 ...
Page 104: ...Limit of liability Chapter 3 Legal information 3 12 phn 2510_002v000 Mar 2012 ...
Page 122: ...Notifications Chapter 4 Reference information 4 18 phn 2510_002v000 Mar 2012 ...
Page 152: ...Installing the PoE power supply Chapter 5 Installation 5 30 phn 2510_002v000 Mar 2012 ...