Ordering components
Chapter 2: Planning considerations
2-28
phn-2510_002v000 (Mar 2012)
Item
Notes
Cable grounding kits
One kit is required per drop cable
grounding point.
‘Cable Grounding Kits For 1/4" And
3/8" Cable’. Cambium part number
01010419001.
Kit contents: grounding cable, self-
amalgamating tape, PVC tape, tie-
wraps, bolts, washers and nuts.
Lightning Protection Unit (LPU) kits
Two kits are required per standard
link.
‘LPU End Kit PTP 250/300/500’.
Cambium part number WB2978.
Kit contents: one LPU, one grounding
cable, nuts, bolts and two cable
glands.
Indoor CAT5e cable
The connected network equipment must
feature screened RJ45 connectors and must
be connected to ground, otherwise the PoE
power supply will not be grounded.
To connect the PoE power supply to
network equipment, use screened
cable that meets this specification:
x
Screening: Must be either foil
screen (FTP) or braided screen
(STP) cable.
x
Connectors: Must use screened
RJ45 connectors with metal shells
at both ends.
x
Electrical connection: There must
be a continuous electrical
connection between both
screened connectors.
Summary of Contents for PTP 250
Page 1: ...Cambium PTP 250 User Guide System Release 250 02 01 ...
Page 8: ...Safety and regulatory information VI phn 2510_002v000 Mar 2012 ...
Page 20: ...List of Tables xii phn 2510_002v000 Mar 2012 ...
Page 58: ...System management Chapter 1 Product description 1 30 phn 2510_002v000 Mar 2012 ...
Page 104: ...Limit of liability Chapter 3 Legal information 3 12 phn 2510_002v000 Mar 2012 ...
Page 122: ...Notifications Chapter 4 Reference information 4 18 phn 2510_002v000 Mar 2012 ...
Page 152: ...Installing the PoE power supply Chapter 5 Installation 5 30 phn 2510_002v000 Mar 2012 ...