PTP 250 User Guide
Site planning
phn-2510_002v000 (Mar 2012)
2-7
Maximum cable lengths
The maximum permitted lengths of interface cables in PTP 250 installations are specified
in
Table 6
.
Table 6
Maximum cable lengths
Interface type
Interface
Maximum
length
Ethernet power
and data
ODU to network terminating equipment.
100 m (330 ft)
Wind loading
Ensure that the supporting structure will not be prone to excessive wind loading.
Antennas and equipment mounted on towers or buildings will subject the mounting
structure to significant lateral forces when there is appreciable wind. Antennas are
normally specified by the amount of force (in pounds) for specific wind strengths. The
magnitude of the force depends on both the wind strength and size of the antenna.
The ODU, with or without the integral antenna, is essentially a flat structure. The
magnitude of the lateral force can be estimated from surface area and wind speed.
Calculation of lateral force (metric)
The magnitude of the lateral force can be estimated from:
Force (in kilograms) = 0.1045aV
2
Where:
Is:
a
surface area in square meters
V
wind speed in meters per second
Summary of Contents for PTP 250
Page 1: ...Cambium PTP 250 User Guide System Release 250 02 01 ...
Page 8: ...Safety and regulatory information VI phn 2510_002v000 Mar 2012 ...
Page 20: ...List of Tables xii phn 2510_002v000 Mar 2012 ...
Page 58: ...System management Chapter 1 Product description 1 30 phn 2510_002v000 Mar 2012 ...
Page 104: ...Limit of liability Chapter 3 Legal information 3 12 phn 2510_002v000 Mar 2012 ...
Page 122: ...Notifications Chapter 4 Reference information 4 18 phn 2510_002v000 Mar 2012 ...
Page 152: ...Installing the PoE power supply Chapter 5 Installation 5 30 phn 2510_002v000 Mar 2012 ...