Engine Management Module (EMM)
Shutdown Mode
4
Shutdown Mode
Outboard “shutdown” will occur if specific faults
are detected by the
EMM
.
Conditions that initiate shutdown
Code 57 occurs when the
EMM
detects abnor-
mally high RPM relative to the TPS position. This
condition could be caused by uncontrolled fuel
entering the combustion cycle. Before removing
the code and STARTING the outboard, find and
repair the cause.
•
Check for external fuel leakage that could allow
fuel and/or vapor to enter the engine through
the air intake.
•
Check for internal fuel leakage from a leaking
injector or vapor separator vent hose.
Recovery
To recover from shutdown mode, the
EMM
must
NOT detect the related fault at start-up. The out-
board will not restart until the cause of the
occurred service code is resolved (code 29 and
31) and the code is cleared using diagnostics soft-
ware (code 33 and 57). Then, the
EMM
must be
turned OFF and ON again.
IMPORTANT:
Shutdown related to code 57 or 33
requires the removal of the
Occurred
service code.
Use
Evinrude Diagnostics
software to clear a code
57 or 33.
Diagnostic Soft-
ware Functions
The
EMM
saves valuable information about the
outboard and its running history. This information
can be used for troubleshooting, for checking
parts information, and for making adjustments to
the system.
Use
Evinrude
Diagnostics
software, version 5.1 or
higher, and a laptop computer to access program
information.
IMPORTANT:
For software help, refer to the
“Help” menu in the software.
Communication
Locate the diagnostic connector on the engine.
Remove the cover and install the Diagnostic Inter-
face Cable (P/N 437955).
Connect the 9-pin connector of the interface cable
directly to the computer’s serial port.
The
EMM
must turn ON before it will communicate
with the computer.
Power is normally supplied to the
EMM
when the
key switch is ON. Switched B+ (12 V) enters the
EMM
at pin 21 (purple) of the
EMM
J1-B connec-
tor.
The
EMM
is also turned ON when it begins to
receive AC voltage from the stator while the out-
board is being cranked.
WARNING
If the engine shuts OFF and the “CHECK
ENGINE” light or EMM SENSOR FAULT LED
is flashing, the engine cannot be restarted. A
hazardous fuel condition may exist which
could result in a fire or explosion.
Code 29
Excessive
EMM
temperature
Code 31
Excessive engine temperature
Code 33
Excessive NO OIL condition
Code 57
High RPM with low TPS setting
1.
Cover
2.
Engine harness diagnostic connector
005021
1
2
Summary of Contents for EVINRUDE E-TEC BE225HGXABA
Page 163: ...Oiling System Oil Supply Diagrams 163 8 008208R Port Side View Starboard Side View ...
Page 165: ...Oiling System Oil Supply Diagrams 165 8 008432R Port Side View Starboard Side View ...
Page 167: ...Oiling System Oil Recirculation Diagrams 167 8 008207R Starboard View Port View ...
Page 251: ...Powerhead Powerhead Views 251 11 Powerhead Views Port Hose Routings 3 3 L models 007153 ...
Page 252: ...252 Powerhead Powerhead Views Starboard Hose Routings 3 3 L models 007154 ...
Page 253: ...Powerhead Powerhead Views 253 11 Port Hose Routings 3 4 L models 008503 ...
Page 254: ...254 Powerhead Powerhead Views Starboard Hose Routings 3 4 L models 008502 ...
Page 255: ...Powerhead Powerhead Views 255 11 Port 3 3 L models 008448 ...
Page 256: ...256 Powerhead Powerhead Views Starboard 3 3 L models 008449 ...
Page 257: ...Powerhead Powerhead Views 257 11 Port 3 4 L models 008441 ...
Page 258: ...258 Powerhead Powerhead Views Starboard 3 4 L models 008442 ...
Page 259: ...Powerhead Powerhead Views 259 11 Front 3 3 L models 008450 ...
Page 260: ...260 Powerhead Powerhead Views Front 3 4 L models 008439 ...
Page 261: ...Powerhead Powerhead Views 261 11 Rear 3 3 L models 007142 ...
Page 262: ...262 Powerhead Powerhead Views Rear 3 4 L models 008440 ...
Page 263: ...Powerhead Powerhead Views 263 11 Top 008438 ...
Page 264: ...264 Powerhead Powerhead Views Starboard ICON models 008504 ...
Page 269: ...Midsection Service Charts 269 12 Muffler 004117R ...
Page 320: ...S 322 ...