220
Evinrude ICON Remote Control System
ICON System Fault Code Chart
150
Throttle Actuator Motion
Fault
The
ESM
tries to move the
throttle actuator, but it will not
attain the commanded posi-
tion.
This is caused by a motion or
over-current error from the
actuator.
The fault message is sent
from the
ESM
to the out-
board’s
EMM
.
FORWARD or REVERSE LED
flashes (depending on gear
position when fault occurred).
With the remote control lever in
NEUTRAL, the NEUTRAL LED
of the affected engine continues
to flash one time per second.
Throttle link arm from
ICON
add-
on kit is not assembled to the out-
board.
Throttle linkage components are
damaged or their movement is
blocked.
Starter cable is not correctly
routed behind the actuator
mounting plate.
Throttle actuator has failed.
Throttle Actuator Motion Check
(Chart 17)
151
Shift Actuator Sensor Fault
The
ESM
has lost the shift
actuator position sensor sig-
nal.
The fault message is sent
from the
ESM
to the out-
board’s
EMM
.
All gear position LED’s flash five
times per second.
With the remote control lever in
NEUTRAL, the NEUTRAL LED
of the affected engine continues
to flash five times per second.
RFI due to excessive spark plug
gap, damaged or worn spark
plugs.
The actuator and the
ESM
are not
connected.
The actuator and
ESM
connec-
tors are damaged.
The wiring of the actuator and
ESM
connectors are in the wrong
locations.
Shift actuator position sensor
failed.
Shift Actuator Sensor Check
(Chart 18)
152
Shift Actuator Motion Fault
The
ESM
tries to move the
shift actuator, but it will not
attain the commanded posi-
tion.
This is caused by a motion or
over-current error on the actu-
ator itself.
The fault message is sent
from the
ESM
to the out-
board’s
EMM
.
FORWARD or REVERSE LED
flashes (depending on gear
position when fault occurred).
With the remote control lever in
NEUTRAL, the NEUTRAL LED
of the affected engine continues
to flash one time per second.
ICON
shift link is not assembled
to the outboard.
Shift linkage components are
damaged or their movement is
blocked.
Shift stroke is not calibrated cor-
rectly.
Shift actuator has failed.
Shift Actuator Motion Check
(Chart 20)
Fault Code Description
LED Indicators
Possible Causes and
Flowchart Reference
Summary of Contents for EVINRUDE E-TEC BE225HGXABA
Page 163: ...Oiling System Oil Supply Diagrams 163 8 008208R Port Side View Starboard Side View ...
Page 165: ...Oiling System Oil Supply Diagrams 165 8 008432R Port Side View Starboard Side View ...
Page 167: ...Oiling System Oil Recirculation Diagrams 167 8 008207R Starboard View Port View ...
Page 251: ...Powerhead Powerhead Views 251 11 Powerhead Views Port Hose Routings 3 3 L models 007153 ...
Page 252: ...252 Powerhead Powerhead Views Starboard Hose Routings 3 3 L models 007154 ...
Page 253: ...Powerhead Powerhead Views 253 11 Port Hose Routings 3 4 L models 008503 ...
Page 254: ...254 Powerhead Powerhead Views Starboard Hose Routings 3 4 L models 008502 ...
Page 255: ...Powerhead Powerhead Views 255 11 Port 3 3 L models 008448 ...
Page 256: ...256 Powerhead Powerhead Views Starboard 3 3 L models 008449 ...
Page 257: ...Powerhead Powerhead Views 257 11 Port 3 4 L models 008441 ...
Page 258: ...258 Powerhead Powerhead Views Starboard 3 4 L models 008442 ...
Page 259: ...Powerhead Powerhead Views 259 11 Front 3 3 L models 008450 ...
Page 260: ...260 Powerhead Powerhead Views Front 3 4 L models 008439 ...
Page 261: ...Powerhead Powerhead Views 261 11 Rear 3 3 L models 007142 ...
Page 262: ...262 Powerhead Powerhead Views Rear 3 4 L models 008440 ...
Page 263: ...Powerhead Powerhead Views 263 11 Top 008438 ...
Page 264: ...264 Powerhead Powerhead Views Starboard ICON models 008504 ...
Page 269: ...Midsection Service Charts 269 12 Muffler 004117R ...
Page 320: ...S 322 ...