Cascaded FICON fabric merge
25
Resolving merge conflicts
You can resolve the following types of switch configuration conflicts:
•
Domain ID
•
TOV
•
Buffer To Buffer Credit
•
Disable Device Probe
NOTE
This test will be skipped if all primary and secondary fabric switches are found to be Fabric OS
v7.0 and above.
•
Route Priority Per Frame
•
Sequence Level Switching
•
Suppress Class F
•
Long Distance Setting
•
Data Field Size
•
VC Priority
Note that not all tests support resolution. If a test supports resolution, the Description column
contains the text 'Resolvable'.
To resolve merge conflicts, complete the following steps.
1. Select the failed test where the Description column contains the text 'Resolvable'.
2. Click Resolve.
A “The switches in fabric
Name
will be disabled prior to making the configuration change. The
switches will be reenabled after the configuration changes are applied. Please confirm to
proceed.” warning message displays.
3. Click OK on the warning message.
The values of the Fabric chosen on the Set up merge options screen are applied to all devices
in the second fabric. Once the settings are applied the test is run again and the merge results
are updated.
If the test passes, go to
step 4
.
If an error occurs, an error message displays. You must use Web Tools or the CLI to resolve this
conflict. Click OK on the error message and go to
step 4
.
If you are resolving a domain ID error, there may be multiple switches involved. If multiple
switches have the domain ID error, the Configure Domain IDs dialog box displays listing all
devices that have domain ID conflict.
a. Select the device you want to resolve the domain ID for in the Available Switches table and
click the right arrow button.
b. Select a new domain ID for the device from the Domain ID list.
c. Repeat steps a and b for each device in the Available Switches table.
d. Click OK on the Configure Domain IDs dialog box.
4. Repeat
step 1
through
step 3
until all resolvable tests pass.
Summary of Contents for Network Advisor 12.0.0
Page 36: ...xxxvi Brocade Network Advisor SAN User Manual 53 1002696 01...
Page 82: ...34 Brocade Network Advisor SAN User Manual 53 1002696 01 License downgrade 2...
Page 86: ...38 Brocade Network Advisor SAN User Manual 53 1002696 01 Uninstalling a patch 3...
Page 122: ...74 Brocade Network Advisor SAN User Manual 53 1002696 01 VM Manager discovery 4...
Page 184: ...136 Brocade Network Advisor SAN User Manual 53 1002696 01 Fabric tracking 5...
Page 214: ...166 Brocade Network Advisor SAN User Manual 53 1002696 01 User profiles 6...
Page 284: ...236 Brocade Network Advisor SAN User Manual 53 1002696 01 User defined performance monitors 8...
Page 320: ...272 Brocade Network Advisor SAN User Manual 53 1002696 01 Grouping on the topology 9...
Page 434: ...386 Brocade Network Advisor SAN User Manual 53 1002696 01 Port Auto Disable 12...
Page 442: ...394 Brocade Network Advisor SAN User Manual 53 1002696 01 Exporting Host port mapping 13...
Page 450: ...402 Brocade Network Advisor SAN User Manual 53 1002696 01 Exporting storage port mapping 14...
Page 536: ...488 Brocade Network Advisor SAN User Manual 53 1002696 01 Virtual FCoE port configuration 16...
Page 552: ...504 Brocade Network Advisor SAN User Manual 53 1002696 01 Security configuration deployment 17...
Page 878: ...830 Brocade Network Advisor SAN User Manual 53 1002696 01 Removing thresholds 24...
Page 922: ...874 Brocade Network Advisor SAN User Manual 53 1002696 01 VLAN routing 26...
Page 990: ...942 Brocade Network Advisor SAN User Manual 53 1002696 01 SAN Connection utilization 29...
Page 1138: ...1090 Brocade Network Advisor SAN User Manual 53 1002696 01 Call Home Event Tables B...
Page 1144: ...1096 Brocade Network Advisor SAN User Manual 53 1002696 01 IP Performance monitoring events C...
Page 1186: ...1138 Brocade Network Advisor SAN User Manual 53 1002696 01 Regular Expressions F...
Page 1486: ...1438 Brocade Network Advisor SAN User Manual 53 1002696 01 Views H...