970
Brocade Network Advisor SAN User Manual
53-1002696-01
Viewing a policy monitor report
31
Fabric Checks — Fabric checks provide the following information for each selected check:
Name — Fabric name.
Status — Result of the check and reason for failure if known. Valid results include
Passed, Partially Failed, Failed, Not Applicable, and Unknown.
Fabric checks include the following options:
Check zoning is enabled
Check that all zones belong to at least one zone configuration
Check the number of initiator ports zoned to each storage port is less than
Configured_Value
. This check provides the following additional detail for this check:
-
Storage Port — WWN of the storage port.
-
Initiator Count — Number of initiator ports zoned to the storage port.
-
Initiator Port — WWN of the initiator port.
-
Zone — Zone name containing the initiator/storage port zoning pair.
Switch Checks — Switch checks provide the following information for each selected check:
Name — Product name.
Status — Result of the check and reason for failure if known. Valid results include
Passed, Partially Failed, Failed, Not Applicable, and Unknown.
Switch Checks include the following options:
Switch — Check for at least
Configured_Minimum_Value
connections to neighboring
switches. This check provides the following additional detail for this check:
-
Neighboring Switch — Name of the neighboring switch.
-
Connection Count — Number of connections to the neighboring switch.
Switch — Check for HTTPS (secure HTTP) configuration. This check provides the
following additional detail for this check:
-
HTTPs Status — Whether HTTPS is enabled or disabled on the product.
-
HTTP Status — Whether HTTP is enabled or disabled on the product.
Switch — Check if the product is configured to send events to this server.
Switch — Check if the product is configured to send Upload Failure Data Capture to an
FTP server.
Switch - Check for SSH (secure Telnet) configuration.This check provides the following
additional detail for this check:
-
SSH Status — Whether SSH is enabled or disabled on the product.
-
Telnet Status — Whether Telnet is enabled or disabled on the product.
Summary of Contents for Network Advisor 12.0.0
Page 36: ...xxxvi Brocade Network Advisor SAN User Manual 53 1002696 01...
Page 82: ...34 Brocade Network Advisor SAN User Manual 53 1002696 01 License downgrade 2...
Page 86: ...38 Brocade Network Advisor SAN User Manual 53 1002696 01 Uninstalling a patch 3...
Page 122: ...74 Brocade Network Advisor SAN User Manual 53 1002696 01 VM Manager discovery 4...
Page 184: ...136 Brocade Network Advisor SAN User Manual 53 1002696 01 Fabric tracking 5...
Page 214: ...166 Brocade Network Advisor SAN User Manual 53 1002696 01 User profiles 6...
Page 284: ...236 Brocade Network Advisor SAN User Manual 53 1002696 01 User defined performance monitors 8...
Page 320: ...272 Brocade Network Advisor SAN User Manual 53 1002696 01 Grouping on the topology 9...
Page 434: ...386 Brocade Network Advisor SAN User Manual 53 1002696 01 Port Auto Disable 12...
Page 442: ...394 Brocade Network Advisor SAN User Manual 53 1002696 01 Exporting Host port mapping 13...
Page 450: ...402 Brocade Network Advisor SAN User Manual 53 1002696 01 Exporting storage port mapping 14...
Page 536: ...488 Brocade Network Advisor SAN User Manual 53 1002696 01 Virtual FCoE port configuration 16...
Page 552: ...504 Brocade Network Advisor SAN User Manual 53 1002696 01 Security configuration deployment 17...
Page 878: ...830 Brocade Network Advisor SAN User Manual 53 1002696 01 Removing thresholds 24...
Page 922: ...874 Brocade Network Advisor SAN User Manual 53 1002696 01 VLAN routing 26...
Page 990: ...942 Brocade Network Advisor SAN User Manual 53 1002696 01 SAN Connection utilization 29...
Page 1138: ...1090 Brocade Network Advisor SAN User Manual 53 1002696 01 Call Home Event Tables B...
Page 1144: ...1096 Brocade Network Advisor SAN User Manual 53 1002696 01 IP Performance monitoring events C...
Page 1186: ...1138 Brocade Network Advisor SAN User Manual 53 1002696 01 Regular Expressions F...
Page 1486: ...1438 Brocade Network Advisor SAN User Manual 53 1002696 01 Views H...