Brocade Network Advisor SAN User Manual
1289
53-1002696-01
Database tables and fields
H
TABLE 302
SFLOW_MINUTE_SUMMARY
Field
Definition
Format
Size
SLNUM
This column is used to store a counter value to
identify the total row count.
bigserial
TIME_IN_SECONDS Data
collection time in seconds.
int
DEVICE_ID
ID of the product which sends the sflow traffic.
int
FRAMES
Number of frames transmitted through the sflow
sample collected.
bigint
BYTES
Number of bytes transmitted through the sflow
sample collected.
bigint
IN_PORT_TYPE
Port type of the incoming traffic interface. For VCS
member the value of,
•
0 means its edge port
•
1 means its fabric port.
For other devices Default value is 0.
smallint
OUT_PORT_TYPE
Port type of the outgoing traffic interface. For VCS
member the value of,
•
0 means its edge port
•
1 means its fabric port.
For other devices Default value is 0
smallint
TABLE 303
SFLOW_MINUTE_VLAN
Field
Definition
Format
Size
SLNUM
This column is used to store a counter value to
identify the total row count.
bigserial
TIME_IN_SECONDS Data
collection time in seconds.
int
DEVICE_ID
ID of the product which sends the sflow traffic.
int
FRAMES
Number of frames transmitted through the sFlow
sample collected.
bigint
BYTES
Number of bytes transmitted through the sFlow
sample collected.
bigint
IN_VLAN
Vlan ID of the incoming traffic interface.
smallint
OUT_VLAN
Vlan ID of the outgoing traffic interface.
smallint
IN_PORT_TYPE
Port type of the incoming traffic interface. For VCS
member the value of,
•
0 means its edge port.
•
1 means its fabric port.
For other devices Default value is 0.
smallint
OUT_PORT_TYPE
Port type of the outgoing traffic interface. For VCS
member the value of,
•
0 means its edge port.
•
1 means its fabric port.
For other devices Default value is 0.
smallint
Summary of Contents for Network Advisor 12.0.0
Page 36: ...xxxvi Brocade Network Advisor SAN User Manual 53 1002696 01...
Page 82: ...34 Brocade Network Advisor SAN User Manual 53 1002696 01 License downgrade 2...
Page 86: ...38 Brocade Network Advisor SAN User Manual 53 1002696 01 Uninstalling a patch 3...
Page 122: ...74 Brocade Network Advisor SAN User Manual 53 1002696 01 VM Manager discovery 4...
Page 184: ...136 Brocade Network Advisor SAN User Manual 53 1002696 01 Fabric tracking 5...
Page 214: ...166 Brocade Network Advisor SAN User Manual 53 1002696 01 User profiles 6...
Page 284: ...236 Brocade Network Advisor SAN User Manual 53 1002696 01 User defined performance monitors 8...
Page 320: ...272 Brocade Network Advisor SAN User Manual 53 1002696 01 Grouping on the topology 9...
Page 434: ...386 Brocade Network Advisor SAN User Manual 53 1002696 01 Port Auto Disable 12...
Page 442: ...394 Brocade Network Advisor SAN User Manual 53 1002696 01 Exporting Host port mapping 13...
Page 450: ...402 Brocade Network Advisor SAN User Manual 53 1002696 01 Exporting storage port mapping 14...
Page 536: ...488 Brocade Network Advisor SAN User Manual 53 1002696 01 Virtual FCoE port configuration 16...
Page 552: ...504 Brocade Network Advisor SAN User Manual 53 1002696 01 Security configuration deployment 17...
Page 878: ...830 Brocade Network Advisor SAN User Manual 53 1002696 01 Removing thresholds 24...
Page 922: ...874 Brocade Network Advisor SAN User Manual 53 1002696 01 VLAN routing 26...
Page 990: ...942 Brocade Network Advisor SAN User Manual 53 1002696 01 SAN Connection utilization 29...
Page 1138: ...1090 Brocade Network Advisor SAN User Manual 53 1002696 01 Call Home Event Tables B...
Page 1144: ...1096 Brocade Network Advisor SAN User Manual 53 1002696 01 IP Performance monitoring events C...
Page 1186: ...1138 Brocade Network Advisor SAN User Manual 53 1002696 01 Regular Expressions F...
Page 1486: ...1438 Brocade Network Advisor SAN User Manual 53 1002696 01 Views H...