Brocade Network Advisor SAN User Manual
805
53-1002696-01
High integrity fabrics overview
23
•
A policy must be set that limits connectivity to only the switches within the same fabric. Fabric
binding is a security method for restricting switches that may join a fabric. For Fabric OS
switches, fabric binding is implemented by defining a switch connection control (SCC) policy
that prevents unauthorized switches from joining a fabric.
•
Dynamic Load Sharing (DLS) should be disabled. If DLS is not disabled, DLS automatically
adjusts routes when a new ISL is added, and when an ISL is taken offline and brought online
again. This process may result in dropped frames.
NOTE
Port binding is a security method for restricting devices that connect to particular switch ports. Port
binding should never be used in FICON environments. The FICON channel cannot be added to the
port binding list.
Activating high integrity fabrics
To activate a HIF, complete the following steps.
1. Select Configure > High Integrity Fabric.
The High Integrity Fabric dialog box displays (
Figure 364
).
FIGURE 364
High Integrity Fabric dialog box
2. Select the fabric on which you want to activate HIF from the Fabric Name list.
The HIF status displays in the High Integrity Fabric field.
3. Click Activate.
HIF activates the Switch Connection Control (SCC) policy, sets Insistent Domain ID, and sets
the Fabric Wide Consistency Policy (FWCP) for SCC in strict mode.
Summary of Contents for Network Advisor 12.0.0
Page 36: ...xxxvi Brocade Network Advisor SAN User Manual 53 1002696 01...
Page 82: ...34 Brocade Network Advisor SAN User Manual 53 1002696 01 License downgrade 2...
Page 86: ...38 Brocade Network Advisor SAN User Manual 53 1002696 01 Uninstalling a patch 3...
Page 122: ...74 Brocade Network Advisor SAN User Manual 53 1002696 01 VM Manager discovery 4...
Page 184: ...136 Brocade Network Advisor SAN User Manual 53 1002696 01 Fabric tracking 5...
Page 214: ...166 Brocade Network Advisor SAN User Manual 53 1002696 01 User profiles 6...
Page 284: ...236 Brocade Network Advisor SAN User Manual 53 1002696 01 User defined performance monitors 8...
Page 320: ...272 Brocade Network Advisor SAN User Manual 53 1002696 01 Grouping on the topology 9...
Page 434: ...386 Brocade Network Advisor SAN User Manual 53 1002696 01 Port Auto Disable 12...
Page 442: ...394 Brocade Network Advisor SAN User Manual 53 1002696 01 Exporting Host port mapping 13...
Page 450: ...402 Brocade Network Advisor SAN User Manual 53 1002696 01 Exporting storage port mapping 14...
Page 536: ...488 Brocade Network Advisor SAN User Manual 53 1002696 01 Virtual FCoE port configuration 16...
Page 552: ...504 Brocade Network Advisor SAN User Manual 53 1002696 01 Security configuration deployment 17...
Page 878: ...830 Brocade Network Advisor SAN User Manual 53 1002696 01 Removing thresholds 24...
Page 922: ...874 Brocade Network Advisor SAN User Manual 53 1002696 01 VLAN routing 26...
Page 990: ...942 Brocade Network Advisor SAN User Manual 53 1002696 01 SAN Connection utilization 29...
Page 1138: ...1090 Brocade Network Advisor SAN User Manual 53 1002696 01 Call Home Event Tables B...
Page 1144: ...1096 Brocade Network Advisor SAN User Manual 53 1002696 01 IP Performance monitoring events C...
Page 1186: ...1138 Brocade Network Advisor SAN User Manual 53 1002696 01 Regular Expressions F...
Page 1486: ...1438 Brocade Network Advisor SAN User Manual 53 1002696 01 Views H...