82
en | Maintenance and troubleshooting
Conettix Universal Dual Path Communicator
2017.11 | 05 | F.01U.311.207
Installation and Operation Manual
Bosch Security Systems, Inc.
Flash pattern
Function
Flashes once every 1 sec
Normal state. Indicates normal operation.
3 quick flashes
Communication error state. Indicates the
module is unable to communicate on the
cellular network.
Off
LED trouble state. Module is not powered, or
some other trouble condition prohibits the
module from controlling the heartbeat LED.
Tab.
11.8:
Cellular module diagnostic LED patterns
SYSTEM TROUBLE LED patterns
Flash pattern
Function
Off
Indicates normal operations.
Flashing
Indicates Ethernet communication errors. Refer to
SYSTEM TROUBLE Flashing (one flash) - Ethernet table
for more information.
Flashing
Indicates cellular communication errors. Refer to
SYSTEM TROUBLE Flashing (two flashes) - Cellular
table for more information.
Flashing
Indicates a communication trouble or failure. Verify IP
address and port numbers entered in the central
station receiver. Make sure the account is enabled in
the receiver. Make sure there is no IP network IP
problem preventing the B465 from reaching the
receiver.
Flashing
Indicates multiple communication errors. Check the
B465 USB status menu for additional information to
help correct the problem.
On Steady
Indicates all non IP communication troubles. For
example low, or missing battery, phone lines are off the
hook for more than 2 minutes, or there is a
configuration issue.
Tab.
11.9:
SYSTEM TROUBLE LED descriptions
Summary of Contents for B465
Page 1: ...Conettix Universal Dual Path Communicator B465 en Installation and Operation Manual ...
Page 2: ......
Page 114: ......