44
en | Configuration and Diagnostics
Conettix Universal Dual Path Communicator
2017.11 | 05 | F.01U.311.207
Installation and Operation Manual
Bosch Security Systems, Inc.
6.3.1
Menu Map
The map below show the complete USB menu structure.
Standard Communication
Configuration
Status
Signal Strength
1
3
4
2
Main
Back
Basic Status
1
0
Advanced Status
2
Product Versions
Alternate Network Technology
3
4
Back
Account Number/NNC Number
1
0
Preferred Network Technology
2
Primary Receiver
Back
Ethernet
Cellular
1
2
0
0
Back
1
Port Number: 7700
2
Ethernet IP Address/Host Name
3
Ethernet Supervision Time
4
Cellular IP Address/Host Name
5
Cellular Supervision Time
0
Back
1
No Supervision
2
90 Seconds - (NFPA 72 2007)
3
180 Seconds - (ULC S304/S559)
4
200 Seconds - (UL 1610)
5
300 Seconds- NFPA 72 2010
6
1 Hour - (NFPA 72 2013)
7
4 Hours
8
24 Hours
0
Back
1
No Supervision
2
90 Seconds - (NFPA 72 2007)
3
180 Seconds - (ULC S304/S559)
4
200 Seconds - (UL 1610)
5
300 Seconds- (NFPA 72 2010)
6
1 Hour - (NFPA 72 2013)
7
4 Hours
8
24 Hours
3
Advanced
Communication
Configuration
0
Back
1
Account Setup
0
Back
1
Account Number: 0000, NNC Number: 00000000
2
Preferred Network Technology: Ethernet
3
Alternate Network Technology
4
* Number of Receiver(s)
Back
Ethernet
Cellular
1
2
0
Disabled
Enabled
N
Y
1
2
2
**Receiver Setup
4
Cellular IP Address/Host Name
5
Cellular Supervision Time
0
Back
1
Port Number: 7700
2
Ethernet IP Address/Host Name
3
Ethernet Supervision Time
6
AES Encryption
0
1
2
3
4
5
6
7
Back
No Supervision
90 Seconds - (NFPA 72 2007)
180 Seconds - (ULC S304/S559)
200 Seconds - (UL 1610)
300 Seconds- (NFPA 72 2010)
1 Hour - (NFPA 72 2013)
4 Hours
24 Hours
8
0
1
2
3
4
5
6
7
Back
No Supervision
90 Seconds - (NFPA 72 2007)
180 Seconds - (ULC S304/S559)
200 Seconds - (UL 1610)
300 Seconds- (NFPA 72 2010)
1 Hour - (NFPA 72 2013)
4 Hours
24 Hours
8
0
1
2
3
4
Back
Disabled
128 Bits
192 Bits
256 Bits
7
Enter AES Encryption Key
0
Back
1
Primary Receiver
2
Secondary Receiver
(uses same options as
Primary Receiver)
** If you only have one receiver selected, then
you do not see the menu selection for
Primary
Receiver
and
Secondary Receive
r.
Selection Receiver Setup takes you directly to
the
Primary Receiver
configuration menu.
* When
Number of Receiver(s)
option is set to “2”,
Secondary Receiver
options display in
Advanced Communication Configeration
=>
Receiver Setup
menu.
5
6
7
8
Substitute Account Number:
Alternate Account Number: None
Cloud Remote Connect (Ethernet)
Disabled
Enabled
N
Y
Disabled
Enabled
N
Y
Cloud Remote Connect (Cellular)
Disabled
Enabled
N
Y
Summary of Contents for B465
Page 1: ...Conettix Universal Dual Path Communicator B465 en Installation and Operation Manual ...
Page 2: ......
Page 114: ......