84
en | Maintenance and troubleshooting
Conettix Universal Dual Path Communicator
2017.11 | 05 | F.01U.311.207
Installation and Operation Manual
Bosch Security Systems, Inc.
Heartbeat
LED
RX LED
Plug-in Status LED
Function
On Steady
Flashing (three flashes)
Off
Indicates a cellular
modem failure. Verify
the plug-in
module is firmly
inserted into the
module connector. If
the problem still
persists replace with
another plug-in
module to see if the
problem is corrected.
Flashing
Flashing (four flashes)
On Steady
Indicates a cellular
DNS Lookup error.
Check the name
entered to verify it
was entered
correctly.
Flashing
Flashing (five flashes)
On Steady
Indicates no
activation. Check with
your service provider
to make sure the
cellular module was
activated.
Flashing
Flashing (six flashes)
On Steady
Indicates an invalid
access point. Check
the APN against the
APN required by your
service provider.
Flashing
Off
Flashing (one flash)
Indicates there are no
towers available for
the service provider.
Try positioning the
antenna in a different
location. If that does
not work, try
changing to a
different service
provider or cellular
plug-in module that
using the other
technology.