Conettix Universal Dual Path Communicator
Communication Configuration | en
63
Bosch Security Systems, Inc.
Installation and Operation Manual
2017.11 | 05 | F.01U.311.207
–
192-bit - 24 bytes
–
256-bit - 32 bytes
Select the key size for AES encryption.
USB Menu Location
[3] Advanced Communication Configuration > [2] Receiver Setup > [1] Primary Receiver > [6]
AES Encryption
7.7.7
AES Encryption Key
Default
: <Default> (not encrypted)
Selections
: Thirty-two hexadecimal characters represented by an ID (01 to 100).
The AES Encryption Key is based on AES Key Size.
AES key strings are configured
in Config > System > Encryption Key Tab
USB Menu Location
[3] Advanced Communication Configuration > [2] Receiver Setup > [1] Primary Receiver > [7]
AES Encryption Key
7.8
Number of Receivers
Default
:
1
Selections
: 1, 2
–
1 - the B465 uses only one receiver (primary).
–
2 - configure the B465 to use a secondary receiver.
You must set this parameter to 2, to configure the parameters for the secondary receiver.
USB Menu Location
[3] Advanced Communication Configuration > [1] Account Setup > [4} Number of Receivers
7.9
Secondary Receiver
You can configure the B465 to send reports to one or two central station receivers (primary
receiver, secondary receiver). Use the parameters in this section to configure the secondary
receiver.
To access these parameters for the secondary receiver, you must set the Number of Receivers
parameter to 2.
[3] Advanced Communication Configuration > [1] Account Setup > [4} Number of Receivers
7.9.1
Ethernet IP Address / Host Name
Default
:
blank
Selections
:
–
IPv4 - 0.0.0.0 to 255.255.255.255
–
IPv6 - 0000:0000:0000:0000:0000:0000:0000:0000 to
FFFF:FFFF:FFFF:FFFF:FFFF:FFFF:FFFF:FFFF
Enter an IPv4 address, an IPv6 address, or host name.
The B465 uses this IP address to send reports to the central station receiver over Ethernet
technology.
Further information
IP Address and Domain Name formats
USB Menu Location
[3] Advanced Communication Configuration > [2] Receiver Setup > [2] Secondary Receiver >
[2] Ethernet IP Address / Host Name