4.5
Install the B465 in the enclosure
Refer to the B465 Quick Start Guide for more information.
Perform the following to install the module.
!
Warning!
The module is static sensitive. Touch earth ground before handling the circuit board to
discharge any static electricity from your body. Use a grounding strap while installing the
circuit board.
4.5.1
Mount the B46 (optional)
Refer to the B46 Install Guide for more information.
4.5.2
Connect earth ground
To help prevent damage from electrostatic discharges or other transient electrical surges,
connect the system to earth ground before making other connections. The icon indicates the
earth ground terminal. Use a recommended earth ground reference, such as a grounding rod
or a metal cold water pipe. Make the connection using 14 AWG (1.8 mm) to 16 AWG (1.5 mm)
wire.
Notice!
Do not use telephone or electrical ground for the earth ground connection. Do not connect
other control panel terminals to earth ground.
!
Caution!
Avoid electrostatic discharge. Always touch the earth ground connection with the icon first,
before beginning work on the control panel.
Notice!
In ground fault enabled systems, you might cause a ground fault when connecting a computer
to the B465 for programming.
4.6
Install the cellular plug-in communicator module (optional)
For cellular communication, use one of the following:
–
B440 Conettix Plug-in Cellular Communicator (3G Verizon, US only)
–
B441 Conettix Plug-in Cellular Communicator (Verizon, US only)
–
B442 Conettix Plug-in GPRS Cellular Communicator (outside the USA where approved)
–
B443 Conettix Plug-in HSPA+ Cellular Communicator (where approved)
–
B444 Conettix Plug-in LTE Cellular Communicator (Verizon, US only)
Install the plug-in module
1.
Power down the B465.
2.
Insert the plug-in module into plug-in stabilizing hole X, and then into the plug-in module
connector. Continue pressing the module into the connector until the retention clip
engages. Refer to callouts 1, 2, and 3 in