Conettix Universal Dual Path Communicator
Communication Configuration | en
59
Bosch Security Systems, Inc.
Installation and Operation Manual
2017.11 | 05 | F.01U.311.207
For example, if the account number in the report from the panel is 1234, the reporting format
for the report is SIA DC-03, and the Alternate Account Number is 1234567890, the B465
replaces 1234 with 567890. The maximum length for an account number in the SIA DC-03
reporting format is 6 digits.
A second example, if the account number in the report from the panel is 1234, the reporting
format for the report is Modem II, and the Alternate Account Number is 8, the B465 replaces
1234 with 0008. The minimum length for an account number in the Modem II reporting format
is 4 digits.
USB Menu Location
[3] Advanced Communication Configuration > [1] Account Setup > [6} Alternate Account
Number
7.4
Preferred Network Technology
Default
:
Ethernet
Selections
:
–
Ethernet - the B465 uses the on-board Ethernet connector for network communication.
–
Cellular - the B465 uses an optional plug-in cellular communicator for network
communication.
The B465 uses the preferred network technology you select here for sending reports to the
central station receiver. If communication to the central station receiver fails and the Alternate
Network Technology is enabled, the B465 tries to send reports using the Alternate Network
Technology.
If you set this parameter to Ethernet, Cellular is the Alternate Network Technology.
If you set this parameter to Cellular, Ethernet is the Alternate Network Technology.
Refer to
Alternate Network Technology, page 59
.
USB Menu Location
[2] Standard Communication Configuration > [2] Preferred Network Technology
- or -
[3] Advanced Communication Configuration > [1] Account Setup > [2} Preferred Network
Technology
7.5
Alternate Network Technology
Default
:
Disabled
Selections
:
–
Enabled - when the Preferred Network Technology is not available, the B465 uses the
Alternate Network Technology.
–
Disabled - the B465 does not use the Alternate Network Technology.
If the Preferred Network Technology parameter is set to Ethernet, then Cellular is the
Alternate Network Technology.
If Preferred Network Technology parameter is set to Cellular, then Ethernet is the Alternate
Network Technology.
Refer to
Preferred Network Technology, page 59
USB Menu Location
[2] Standard Communication Configuration > [3] Preferred Network Technology
- or -
[3] Advanced Communication Configuration > [1] Account Setup > [3} Preferred Network
Technology