Conettix Universal Dual Path Communicator
System Configuration | en
77
Bosch Security Systems, Inc.
Installation and Operation Manual
2017.11 | 05 | F.01U.311.207
This is the passcode you need to access the B465 USB user interface using the Tera Term
serial communication program.
8.9
Test Report
8.9.1
Test Report Interval
Default
:
Disabled
Selections
:
–
Disabled
–
4 hours
–
6 hours
–
12 hours
–
24 hours
The B465 sends a test report to the central station receiver at the interval you select here.
If the parameter
Module Faults set Trouble Output, page 76
is set to enabled and there is a
module fault, the B465 sends a PERIODIC TEST (with system trouble present) report.
If the sensor loop for an enabled
is shorted or open, the B465 sends a
PERIODIC TEST (with system trouble present) report.
If there are no module faults and sensor loops for all inputs are normal (not shorted or open)
the B465 sends a PERIODIC TEST report.
Notice!
This parameter not available in RPS
To save your changes in RPS, connect the B465 with RPS. In the Panel Synchronization
window, click Receive & Overwrite RPS Data.
USB Menu Location
[4] System Configuration > [8] Test Report Settings > [1] Test Report Interval