Conettix Universal Dual Path Communicator
Installation | en
15
Bosch Security Systems, Inc.
Installation and Operation Manual
2017.11 | 05 | F.01U.311.207
4
Installation
Perform the following steps to install the module.
Notice!
B46 External Annunciator installation
Refer to the
B46 External Annunciator Installation Guide
(P/N: F01U312441) prior to installing
the enclosure for B465 module. There is a specific installation sequence you must follow to
avoid damaging the B46 module during the installation process.
4.1
Remove enclosure knockouts
Refer to Figure 4.1 below for knockout locations.
!
Caution!
Insert conduits into the enclosure knockout areas when running wire or cabling to reduce
wire/cable damage.
4.2
Mount the enclosure
Mount one of the following enclosures in the desired location to meet desired UL
requirements:
–
B10 Medium Control Panel Enclosure (white)
–
B10R Medium Control Panel Enclosure (red)
–
B11 Small Control Panel Enclosure (white)
–
B11R Small Control Panel Enclosure (red)
–
D8103 Universal enclosure (this enclosure requires the B12 mounting plate)
–
D8108A Attack Resistant Enclosure (this enclosure requires the B12 mounting plate)
Installing the enclosure:
1.
Remove any knockouts prior to installing the module.
2.
Mount the enclosure in the desired location. Use all enclosure mounting holes. Refer to
the mounting instructions supplied with the selected enclosure.
3.
Pull any necessary wires/phone lines into the enclosure.
Notice!
Electromagnetic interference (EMI) can cause problems on long wire runs
Summary of Contents for B465