Parameter description
Parameter manual
b maXX
®
1000
Document no. 5.07004.03
Baumüller Nürnberg GmbH
98
4.3
P1135
Please note the ACI/AVI switch on the b maXX
®
1000, see
For further information see
and
P1136
Please note the ACI/AVI switch on the b maXX
®
1000, see
For further information see
and
P1137
Please note the ACI/AVI switch on the b maXX
®
1000, see
For further information see
and
P1138
This parameter selects the target of the analog input function.
P1135
Minimale AVI2 Frequenz
0.0 to 100.0 %
EE
Minimum AVI2 frequency
0.0 %
STOP
BM_u_MinimumAVI2Frequency
10:1
P1136
Maximale AVI2 Spannung
0.0 to 10.0 V
EE
Maximum AVI2 voltage
0.1 V
STOP
BM_u_MaximumAVI2Voltage
10:1
P1137
Maximale AVI2 Frequenz
0.0 to 100.0 %
EE
Maximum AVI2 frequency
0.0 %
STOP
BM_u_MaximumAVI2Frequency
10:1
P1138
AI1 Funktionsauswahl
0 to 5
EE
AI1 function selection
0
STOP
BM_u_AI1FunctionSelection
1:1
-
Value
Meaning
0
Disable
1
First frequency source
2
Second frequency source
3
PID set point (PID enable)
4
PID positive feedback
5
PID negative feedback