Basic of CAN
Parameter manual
b maXX
®
1000
Document no. 5.07004.03
Baumüller Nürnberg GmbH
204
B.3
m
Quickstop time
6051
hex
= P1174 (b maXX
®
1000 parameter)
(1= 1/1000s,
⇒
1 s = 1000) the resolution is 10 ms
m
Speed actual value
606C
hex
= P2073 (b maXX
®
1000 parameter)
m
Output current actual value
6078
hex
= P2117 (b maXX
®
1000 parameter)
m
Output Torque actual value
6077
hex
= P2113 (b maXX
®
1000 parameter)
m
Encode value
6064
hex
= P2067 (b maXX
®
1000 parameter)
NAME
Index
Sub-index
Data type
Access
type
Default value
Quick stop time
6051
hex
00
hex
U32
RW
3E8
hex
NAME
Index
Sub-index
Data type
Access
type
Default value
Speed actual value
606C
hex
00
hex
U32
RO
0
hex
NAME
Index
Sub-index
Data type
Access
type
Default value
Output current
actual value
6078
hex
00
hex
U16
RO
0
hex
NAME
Index
Sub-index
Data type
Access
type
Default value
Output torque
actual value
6077
hex
00
hex
U16
RO
0
hex
NAME
Index
Sub-index
Data type
Access
type
Default value
Encode value
6064
hex
00
hex
U32
RO
0
hex