![Baumuller b maXX 1000 Parameter Manual Download Page 198](http://html.mh-extra.com/html/baumuller/b-maxx-1000/b-maxx-1000_parameter-manual_2711401198.webp)
Basic of CAN
Parameter manual
b maXX
®
1000
Document no. 5.07004.03
Baumüller Nürnberg GmbH
198
B.3
Notice for Transmit PDO Communication parameter
At the Sub-index 03
hex
the inhibit time is adjusted, which is the minimal deceleration time for a transmission
interval. The input value is defined as a multiplier of 100.
Sub-index 04
hex
is not used.
Sub-index 05
hex
is for setting the time of timer triggered Transmit PDOs. The resolution is 1 millisecond.
NAME
Index
Sub-
index
Data
type
Access
type
Default Value
4. Transmit PDO Parameter
1803
hex
00
hex
U8
RO
5
hex
COB-ID used by PDO
01
hex
U32
RW
480
hex
+
Node-ID
Transmission Type
02
hex
U8
RW
F0
hex
Inhibit Time
03
hex
U16
RW
0
hex
CMS-Priority Group
04
hex
U8
RW
3
hex
Event Timer
05
hex
U16
RW
0
hex