Structure of controller parameter range
Parameter manual
b maXX
®
1000
Document no. 5.07004.03
Baumüller Nürnberg GmbH
18
4.1
4.1.1
Attributes
Every parameter can have one or more attributes - see detailed parameter description
4.1.2
Reserved bits
In the description of the parameters, especially of the mode parameters and status pa-
rameters several bits are marked as reserved. The bits can obtain an importance with fu-
ture extensions. For these bits the following is valid:
m
In setting parameters the bits are to be set to 0.
m
In status parameters these bits are not to be evaluated.
Attribute
Meaning
A
Parameter only serves as display (identification, operational status,
actual value, etc.)
EE
The parameter is part of the ’central data’ and can be saved in
EEPROM. This parameter will be automatically loaded from the con-
troller’s internal EEPROM when the controller is started.
ON
Changes take effect instantly
STOP
Changes possible only in inhibit or ready for switch-on status
-
The parameter will not be saved (effective for e.g. actual values)