P0807
This parameter sets the up/down mode only for external terminals.
This parameter determines the increase/decrease of the motor frequency when operated
via the multi function inputs (
are set to 10 (up command) or 11
(down command).
P0809
This parameter set the master frequency command source of the b maXX
®
1000.
The factory setting for master frequency command is 1 (digital keypad is optional).
Setting 2:
use the ACI/AVI switch on the b maXX
®
1000 to select ACI or AVI2. When setting to AVI,
AVI2 is indicated.
When the b maXX
®
1000 is controlled by external terminal, please refer to
for
details.
The first/second frequency/operation command is enabled/disabled by multi function in-
put terminals. Please refer to
.
P0807
Hochlauf/Rücklauf Mode
0 to 3
EE
Up/Down Mode
0
STOP
BM_u_UpDownMode
1:1
-
Value
Meaning
0
By digital keypad up/down keys mode
1
Based on acceleration/deceleration time according to
,
,
2
Constant speed (according to
)
3
By pulse input unit (according to
P0809
Quelle der zweiten Hauptfrequenzvorgabe
1 to 255
EE
Source of second master frequency command
0
ON
BM_u_SourceSecondMasterFrequComm
1:1
-
Value
Meaning
255
Digital terminal 15 fixed set value
0
Digital keypad UP/DOWN keys or multi-function inputs UP/DOWN.
Last used frequency saved (digital keypad is optional).
1
0 to +10V from AVI
2
4 to 20mA from ACI or 0 to +10V from AVI2
3
ProDrive communication interface
4
Digital keypad potentiometer
5
CANopen