4.3
Figure 13:
P0805 Line start lockout with external terminals
P0806
This parameter determines the behavior when analog current input ACI is lost.
When set to 1, it will display warning message „AErr“ on the keypad in case of loss of ACI
signal and execute the setting. When ACI signal is recovered, the warning message will
stop blinking. Please press „RESET“ key to clear it.
MI1-DCM
(close)
Output
frequency
=
2 or 3
Change opera-
tion command
source
Output
frequency
=
0 or 1
This action will
follow MI1/DCM
or MI2/DCM
status
(ON is close/
OFF is open)
WARNING
The following
may occur
,
if you do not observe this warning information:
m
personal injury
The line start lockout feature does not guarantee that the motor will never start under this con-
dition. It is possible the motor may be set in motion by a malfunctioning switch.
P0806
ACI Signal fehlt
0 to 2
EE
Loss of ACI Signal
1
STOP
BM_u_LossACISignal
1:1
-
Value
Meaning
0
Decelerate to 0 Hz
1
Coast to stop and display „AErr“
2